Titan™ 118

The Titan™ 118 structural repair system is comprised of a unique, uni-axial carbon fiber fabric, saturated with NRI’s proprietary epoxy system, Titan™-Saturant Epoxy.

The Titan™ 118 carbon fiber is uni-directional fabric with the primary, continuous fibers oriented in the 0° direction. The Titan™-Staturant Epoxy system is a two-part, 100% solid epoxy system designed for use in a wide variety of environments possessing excellent chemical resistance and high temperature ratings. The development of this system was designed to conform to ACI440 standards for nonmetallic composite reinforcing solution ofconcrete.


DatasheetSDS Sheets
InformationTesting DataVideosCase Studies

Typical Applications

  • Structural reinforcement
  • Containment and shear reinforcement
  • Bridge column repair
  • Pile repair
  • Seismic retrofitting


  • Long working time even in hot environments
  • Properties retained even at high temperature use
  • Solvent free, no VOC”s
  • Applicable in damp and wet environments
  • High strength and light weight
  • Manufactured in ISO 9001 certified facility
  • Full factory engineering consultation and support, ensuring safe and successful repairs


300 sq. ft. surface area requires: (2) gallons of Titan Primer Epoxy, (5) gallons TitanSaturant, (1) 12” x 300’ roll (0.3m x 9.1m)


As detailed on individual product data sheets and determined by NRI engineering calculations

Mixing & Mix Ratio

As detailed on individual product datasheets

Pot Life

75 minutes @ 75 ˚F (24 ˚C), less at higher temperatures


  • Application temperature shall be a minimum of 50 ˚F (10 ˚C) and maximum of 280 ˚F (138 ˚C)
  • Relative humidity must be 85% or below
  • Pipe surface must be 5 ˚F (15 ˚C) above dew point

Related Products
The following products are system components of the Titan-118 system:

  • Titan-Primer Epoxy
  • Titan-Saturant
  • Titan-Top Coat (if required)


Titan-118 is an ICC-ES, AC-125, ACI 400.8-13 repair system. Consult NRI Engineering for specified use.

Surface Preparation

Surface preparation shall be in accordance with ACI 546R, ICRI No. 310.1R-2008 and ACI 562-13 detail methods for the repair and surface preparation of concrete.


Installation of the Titan-118 System shall be performed by NRI qualified applicators only. Surface preparation, mixing of epoxy, and installation of the system are to be in accordance with NRI’s Titan-118 Installation Guide, latest revision. Quality control inspection during and after installation of the Titan system shall be performed per NRI’s In-Field Quality Manual, latest revision.

Cleanup and Safety

For proper information regarding the safe handling, storage, and disposal of chemical products, users shall refer to the most recent SDS, latest revision, containing physical, ecological, toxicological, and other safety-related data.

Shelf Life

Epoxy: 12 months
Fabric: 12 months

Storage Conditions

Store indoors in cool, dry, ventilated storage at temperatures below 95 °F (35 °C)
Epoxy: store in original, unopened containers
Fabric: store in original packaging away from moisture or any contaminants


Titan-Saturant: 1 gallon (3.8L) and 5 gallons (19L)
Titan-118 fabric: 12” x 300’ (0.3m x 9.14m) rolls
Typically ships in 12” x 12” x 18” boxes (305mm x 330mm x 1626mm)

Mechanical Properties

Tensile StrengthASTM D3039Primary: 144 ksi (9,928.45 bar)
Elongation @ BreakASTM D30391.2%
Tensile ModulusASTM D303914.7 msi (1,013,529 bar)
Laminate ThicknessPer layer0.028″
Hardness, Shore D @ 75°F (24°C)ASTM D224085

Dry Fiber Properties

Tensile Strength550,000 psi (37,921.17 bar)
Dry Fiber Thickness0.026″
Fiber Architecture0 uni-directional
Weight (per sq yd)17.40 oz per square yard
Lloyd’s Approved FiberYes

Cure Schedule

Temperature Working Time Set Time
50ºF (10ºC)225 minutes 24 hours
60ºF (16ºC) 150 minutes 12 hours
75ºF (24ºC) 75 minutes 6 hours
90ºF (32ºC) 35 minutes 3 hours