PRODUCTS

Syntho-Glass® UV

Syntho-Glass® UV has been specifically designed to be an aesthetically pleasing, non yellowing superior wrapping system to provide UV stabilization for pipe coatings, previous composite repairs or anywhere UV degradation is a concern. Syntho-Glass® UV prevents future corrosion and abrasion due to mechanical impact, frost heave, crevice corrosion, galvanic corrosion, and vibration abrasion at soil to air interface, water to air interface and pipe support areas. This system provides exceptional mechanical and impact protection. Syntho-Glass® UV can be used underwater, underground or on above ground pipes and piles.

 

Description

DatasheetSDS Sheet
InformationTesting DataVideos
Typical Applications

  • UV protection
  • Mechanical protection
  • Abrasion protection
  • Corrosion prevention
  • Protection at soil to air interface
  • Splash zone protection
  • Protection at support areas

Benefits

  • Non yellowing
  • Prevents corrosion
  • Impact/Abrasion resistance
  • Energy absorbing
    Easy to apply
  • No mixing, no measuring ensures consistent glass to resin ratio, therefore consistent results
  • Can be applied in any weather condition, even underwater
  • Contains no solvents

Coverage

As determined by NRI engineering calculations and roll sizes

Thickness

As determined by NRI engineering calculations

Mixing & Mix Ratio

No mixing required

Working Time

60 to 75 minutes @ 75 ˚F (24 ˚C), less at higher temperatures

Limitations

6 month shelf life

Related Products

Syntho-GlassUV can be used on top of any of NRI’s composite reinforcement systems

Design

Designed for mechanical abrasion and UV protection

Surface Preparation

Surface preparation and profiling shall promote continuous intimate contact between the FRP system and pipe by providing a clean, smooth, and circumferential surface. Surface preparation shall be in accordance with SSPC-SP1 “Solvent Cleaning” and SSPC-SP11 “Power Tool Cleaning” with a 1-3 mil surface roughness (25-75 microns) minimum. If an existing coating is present, roughen to degloss. NRI’s composite repair systems are bond-critical and require a strong adhesive bond between the clean pipe and the composite system.

Installation

Installation of the system is to be used in accordance with NRI’s Syntho-Glass UV Installation Guide, latest revision. Quality control inspection during and after installation of the SynthoGlass UV shall be performed per NRI’s Installation Validation Procedure: Quality Control Records, latest revision.

Cleanup and Safety

For proper information regarding the safe handling, storage, and disposal of chemical products, users shall refer to the most recent SDS, latest revision, containing physical, ecological, toxicological, and other safety-related data.

Shelf Life

6 months

Storage Conditions

Store indoors in cool, dry, ventilated storage at temperatures below 95 °F (35 °C)

Packaging

Syntho-Glass ®UV is available in 2”, 3”, 4”, and 8” rolls; packaging varies on size purchased Typically ships in 17” x 15” x 14” boxes (43cm x 38cm x 36cm)

Composite Laminate Properties

PropertyTypical Test Value
Laminate Thickness 0.011” (2.794mm)
Glass Transition (Tg) Temp 180°F (82°C)
Shore D Hardness 70-80
Short Beam Shear Strength 1,148 psi (79.1 bar)

Cure Schedule

Temperature Working Time Set Time
50°F (10°C) 360 minutes 24 hours
60°F (16°C) 220 minutes 8 hours
75°F (24°C) 120 minutes 2 to 3 hours