3″ OD Natural Gas Valve Repair using Trident-Seal

During a service repair, a natural gas distribution valve was damaged, which caused a small leak. The technicians immediate solution was to use NRI’s Trident-Seal in order to stop the leak until a proper repair would take place. Read more below for the full story!
Read more

26″ OD External Corrosion at 10 bar (145 psi)

In Poland, a 26” OD line, with 145 psi was experiencing extreme external corrosion. Shutdown for replacement was not an option and only a short interruption to service was allowed to perform repairs. Learn how NRI provided an ASME PCC-2 compliant repair which could contain a possible leak! Read more below:
Read more

12.75″ OD Natural Gas Line Re-Rating

A Canadian natural gas operator purchased a line that did not meet their safety standards, an inspection of the line showed that the pipe had mechanical damage, specifically a dent. Further, the ASME PCC-2 standard did not provide direction for re-rating the line. The service provider turned to the engineers at NRI for a design solution.  Read […]
Read more

6″ Offshore Pipeline Dent Rehabilitation and Repair with Syntho-Glass XT

A a supply boat impacted a southern California offshore platform, which caused mechanical damage (dents) to the pipeline. The severity of the damage would traditionally result in the shutdown of the pipeline. With NRI’s Syntho-Glass XT the platform did not suffer any shutdowns, and was able to continue operations as usual. Read more below to […]
Read more

8″ Offshore Gas Process Pipeline Repaired & Restored with Syntho-Glass XT in Thailand

In Thailand, an 8″ OD gas processing pipe located offshore was heavily pitted and was in need of urgent repair before a serious maintenance shutdown was required. The repair was performed in two hours and no shutdown was required.
Read more

Historic NRI and IMG Composites Merger Establishes World’s Largest Composite Repair Corporation

Read more

Municipal Sewage Concrete pipe Suffering from Sulfuric Acid Leaks

A municipal sewage concrete pipe is suffering from sulfuric acid leaks. Read more below to see how Syntho-Glass XT was used as a permanent repair on the line.
Read more

12″ OD x 1.5″ OD Tee Rehabilitation with NRI Composites

A 12″ OD line with a number of dead nozzles was experiencing severe internal wall loss. Since it was a diesel line, with an operating pipe temperature was of 375 F, solutions were limited. Because of the difficult geometry, the end user decided to use NRI’s conformable, cold welding products to repair the line while […]
Read more

2″ OD Hydrocarbon Branch Enclosure Encapsulation

Atmospheric corrosion is common among offshore pipes. During a routine inspection, severe atmospheric corrosion was noted on a 2” branch connected to a 10” hydrocarbon / water line. Surface preparation was not possible due to the severe corrosion, so NRI recommended a perimeter seal enclosure to encapsulate the entire branch leg. Read more below to […]
Read more

2″ OD Offshore Flare Engineered Enclosure Repair

During a routine inspection, two serious defects were found on a 2″ flare gas line. When NRI was asked to provide the safest repair option, NRI recommended an annular fill purpose built mechanical enclosure. Read more below to find out how this leak was repaired.
Read more